Tanks and dip charts

Add each underground tank, then paste or open its calibration chart so the app can turn a dip in millimetres into litres.

On this page
  1. Before you start
  2. Add a tank
  3. Add the dip chart
  4. The chart format the app reads
  5. The checks on a chart
  6. Replace a chart
  7. On hold
  8. Next step

This page shows how to add your tanks and give each one its dip chart. The dip chart (calibration chart) turns a dip reading in millimetres into litres. The Owner or a Manager usually does this, with the Setup permission.

To open the screen, select Tanks under Setup in the sidebar. The screen is called Tanks and dip charts.

Before you start

  • Add your products first. Every tank holds one product. Until you do, the screen shows Add products first: every tank holds one product. See Products and prices.
  • Keep each tank's calibration chart ready, in Excel or as a CSV or text file.

Add a tank

  1. Select Add tank.
  2. Type the Tank name, like MS-1 or HSD-2. Each tank needs its own name.
  3. In Holds, choose the product in the tank.
  4. Type the Capacity (litres), like 20000.
  5. Type Order more below (litres). Today shows a reminder when stock falls below this. If you leave it empty, the app uses one fifth of the capacity. For a 20,000 litre tank that is 4,000 litres. It cannot be more than the capacity.
  6. Select Save.

The tank now shows Needs a dip chart in the Dip chart column. To change a tank's details later, select its row.

Add the dip chart

The dip chart box with a pasted chart, its plot and the check result

  1. In the tank's row, select Add dip chart.
  2. Put the chart in. Do one of these:
    • In Excel, select the two columns (dip, then litres) and copy them. Click in Paste the chart and paste.
    • Next to Or open a file (.csv or .txt), choose the chart file.
  3. Read the line beside the plot. It says how many rows were read and where the chart ends, for example "241 rows, from 0 mm to 2,400 mm, ending at 20,000 litres."
  4. Look at the plot. Litres should rise smoothly as the dip rises. A sudden jump or a flat stretch points to a typing mistake.
  5. Check the result under it:
    • It starts at zero, rises all the way and reaches the tank’s capacity. means the chart passed.
    • A red line names the first problem. Fix it (see below) and paste again.
  6. In Where this chart came from (optional), note the source, like “IOCL calibration, March 2024”. When you open a file, its file name is filled in for you.
  7. Select Use this chart. The button works only when the chart has passed the checks.

The tank now shows Dip chart checked.

The chart format the app reads

The app reads two columns on each line: the dip in millimetres first, then the litres.

  • Dip: whole millimetres, digits only, like 1200.
  • Litres: a number, with decimals if you need them, like 19832.4.
  • Between the columns: a tab, a semicolon (;), a comma (,) or spaces. When you copy from Excel, the columns are separated by tabs.
  • Thousands separators: fine when the columns are separated by a tab, a semicolon or spaces, like 1,200 and 19,832.4. In a comma-separated line, write the numbers without them.
  • Order: from 0 mm upwards, one row for each step of the chart. The app does not sort the rows for you.
  • Heading rows: lines before the first row of numbers are skipped, so a heading like "Dip (mm) Litres" is fine.
  • Extra columns: anything after the second column is ignored.
  • Empty lines: skipped.

Do not put units or other text in the number cells, like "1200 mm" or "500 L". Do not put the numbers in quotation marks. Such lines cannot be read.

After the first row of numbers, any line the app cannot read is left out. The app tells you how many, for example 3 lines could not be read and were left out. Find those lines in your sheet and fix them, so no row of the chart is missing.

A CSV file can start like this, and go on in the same way to the top of the tank:

mm,litres
0,0
10,52.6
20,148.9
30,273.1

A chart can have up to 20,000 rows.

The checks on a chart

The app checks every chart against the tank before you can use it. A chart passes when:

Check What you see if it fails
It has at least two rows A dip chart needs at least two rows.
The first row is 0 mm The chart must start at 0 mm.
Each dip is higher than the row before Dip 1200 mm is not above the row before it (1210 mm).
Each litre value is higher than the row before Volume does not rise from the row before it.
The last row is within 1% of the tank's capacity The last row is not within 1% of the tank capacity.

Only the first problem is shown. It names the row by its dip, as your calibration sheet does, for example "At 1,200 mm: Volume does not rise from the row before it." Fix that row and the check runs again at once.

For the 1% check: a 20,000 litre tank needs a last row between 19,800 and 20,200 litres. If the chart is right but the capacity is wrong, select the tank's row and correct Capacity (litres).

Replace a chart

When a tank is calibrated again, select Replace chart in its row and follow the same steps. The new chart is used for every dip from then on. The old chart is kept and not changed. Dips taken earlier keep the litres they were worked out with.

On hold

A tank can show On hold next to its product. This happens when water is found in the tank during the morning checks. See Morning checks.

Next step

Add the dispensers and nozzles that draw from each tank. See Dispensers and nozzles.

Something here does not match your screen, or a step is unclear? Tell us and we will fix the page.