Alerts
See what needs attention at the station, worst first, mark alerts as seen or dealt with, and know which events raise an alert.
Alerts tell you when something at the station needs someone to look: water in a tank, a failed nozzle test, a rejected tanker, a stock variation over the limit, or a licence about to expire. Everyone who can sign in can see the alerts.
Routine sales never show up as alerts.
Open the alerts
Select Alerts in the left menu.
The Alerts card on Today also shows how many alerts are open, for example "1 critical · 2 need action". Select See alerts to open the list. When there is nothing open, it says Nothing needs attention.
The list shows the worst first: critical, then needs action, then for information. Each alert shows:
- what happened, for example Water found in a tank;
- the date and how serious it is: critical, needs action or for information;
- the details, for example "Tank: MS-2 · Water (mm): 12";
- where it stands, and who marked it.
Mark an alert
Each open alert has two buttons:
- Seen: you have read it, but the cause is not fixed yet. The alert then shows Seen, not yet dealt with, with your name.
- Dealt with: the cause is fixed. The alert moves out of the list.
To see alerts that are already dealt with, tick Show dealt with.
Some alerts are marked dealt with for you when the cause is fixed:
- Releasing a tank from hold on Morning checks clears its water alert or its stock variation alert.
- Recording a renewal under Licences & certificates clears that document's reminders.
What raises an alert
| Alert | How serious | When it is raised | What to do |
|---|---|---|---|
| Water found in a tank | critical | A morning water dip is more than 0 mm. The tank goes on hold. | Deal with the water, then release the tank. See Morning checks. |
| Density outside the product range | critical | A morning or reference density at 15 °C is outside the range for petrol or diesel. | Check the reading and the fuel. |
| A nozzle failed its 5-litre test and was switched off | critical | A nozzle was more than 25 ml short. The nozzle is turned off. | Have it repaired, then turn it back on in Setup → Nozzles. |
| A nozzle needs recalibration | needs action | A nozzle was more than 10 ml over, or 11 to 25 ml short. The details show the date it is due by. | Have it recalibrated within 15 days. |
| A tanker was rejected on density | critical | A compartment's density at 15 °C was more than 3.0 kg/m³ from the invoice. | Do not decant. Inform the supply location. See Receive a tanker. |
| Stock variation over the limit | critical | At day close, a tank's variation for the month is over the limit. | Follow the instruction shown at day close. See Stock day and variation. |
| A sudden stock loss in one day | critical | At day close, one day's variation is 100 litres or more short. | Check for leaks or theft. |
| A licence or certificate expires within 30 days | needs action | A document under Licences & certificates expires within 30 days. | Renew it, then record the renewal. See Registers and inspections. |
| A licence or certificate has expired | critical | A document's expiry date has passed. | Renew it, then record the renewal. |
Alerts on the phone
Critical and needs-action alerts are also sent to the phone app as notifications, for the Owner and for Managers who use it. They arrive after the station PC syncs. The phone app has the same alert list, with Seen and Dealt with. See Phone: today and approvals.
Something here does not match your screen, or a step is unclear? Tell us and we will fix the page.