- Why registers matter more than the checks themselves
- The daily checklist
- 1. Morning dip and water dip for every tank
- 2. Density at 15 °C, by 10 AM
- 3. The 5-litre measure on every nozzle
- 4. Tanker receipts with dips before and after
- 5. Closing dip and stock for the day
- The registers an officer asks for
- Stock variation: know your number before the officer does
- When the officer arrives
- A five-minute morning routine
- Frequently asked questions
An inspection rarely goes wrong because a dealer is cheating. It goes wrong because a register has a gap: a morning when density was not written down, a tanker with no after-dip, a 5-litre check that was done but never recorded. The officer can only judge what is on paper, and a missing entry looks the same as a missing check.
This checklist covers what an officer from your oil marketing company (OMC) usually asks to see under the Marketing Discipline Guidelines, and how to keep each item ready every day instead of rebuilding it the night before. The exact format and frequency can differ between companies and between versions of the guidelines, so treat this as a working list and confirm anything you are unsure of with your sales officer.
Why registers matter more than the checks themselves
Most stations do the physical checks: someone dips the tanks, someone runs the 5-litre measure. The weak point is the record. Entries are written at the end of the day from memory, copied from one notebook to another, or corrected with whitener. During an inspection, three things count against you:
- Gaps. A day with no density entry is treated as a day the density was not checked.
- Numbers that do not add up. Opening stock plus receipts minus sales should land near the closing dip. If it does not, the officer will ask why.
- Corrections you cannot explain. A changed figure with no name, time or reason invites more questions than the original mistake.
The fix is not more paperwork. It is writing each figure once, at the time it is taken, in a place that keeps it.
The daily checklist
1. Morning dip and water dip for every tank
Take a product dip and a water dip on every tank before sales start, and convert the product dip to litres with that tank's own calibration chart. Water above zero is a stop sign: the tank should not sell until the manager has checked it and noted what was done.
In PetroKhata the morning checks screen asks for both dips per tank, turns millimetres into litres from the tank's dip chart, and puts a tank with water on hold until a Manager releases it with a note.
2. Density at 15 °C, by 10 AM
Record observed density and temperature from the hydrometer and thermometer for each tank, and the density corrected to 15 °C. Most OMCs expect this before the first sale and no later than 10 AM. Keep the hydrometer jar, the thermometer and the printed ASTM Table 53B (the standard table for correcting density to 15 °C) together, so the reading and its correction are done by the same person at the same time.
PetroKhata works out density at 15 °C from the two readings and shows a warning from 9:15 if any tank is missing. It does not stop sales at 10 AM; it records that the deadline was missed, which is what the register needs to show. One honest caution: our conversion has been tested for behaviour but not yet checked row by row against a printed Table 53B, so compare a few readings with your printed table before you rely on it.
3. The 5-litre measure on every nozzle
Run the stamped 5-litre measure on each nozzle every morning and write down the difference in millilitres, plus or minus. A nozzle that shows a variation should be watched; one that gives short should be kept off and reported, as your OMC instructs. The test fuel goes back into the tank, so it must be taken out of the day's sales figure or the shift will show phantom litres.
PetroKhata asks for the difference for each nozzle, marks it pass, recalibrate or stop against its built-in thresholds, alerts the owner when a nozzle is stopped, and takes the test litres off sales at shift close. Check that those thresholds match what your OMC currently applies, and tell us if they do not.
4. Tanker receipts with dips before and after
Every delivery needs its own record: invoice and truck number, seal check, compartment density against the invoice, retention samples with seal numbers, a dip before decanting and a dip after. The litres received by dip are compared with the invoice and the shortage or excess is written down. We cover this in detail in catching tanker shortages with dip reconciliation.
5. Closing dip and stock for the day
At day close, dip every tank again. Book stock is opening stock plus receipts minus net sales (after test litres). The difference between book stock and the dip is the day's variation, and it adds up across the month.
The registers an officer asks for
| Register | What it holds | How often |
|---|---|---|
| Density register (Annexure 1 in PetroKhata) | Morning density at 15 °C per tank, with observed density and temperature | One per tank per month |
| Stock variation register (Annexure 9 in PetroKhata) | Book stock against dip stock, daily and for the month | Daily, totalled monthly |
| Daily stock register | Opening, receipts, sales, closing by dip, per product | Daily |
| 5-litre test record | Difference in ml per nozzle | Daily |
| Tanker receipt records | Invoice, seals, compartment density, samples, dips before and after | Every delivery |
| Licences and certificates | Explosives licence, weights and measures stamping, calibration and similar | Current copies with expiry dates |
The annexure numbers above are how PetroKhata names its printouts, following the guidelines as we read them. Your OMC's printed formats are the reference: hold one month of PetroKhata output next to your current register and check that every column you are asked for is there.
Stock variation: know your number before the officer does
Every tank loses or gains a little: temperature, evaporation, meter accuracy. The guidelines set a limit on how far the dip may drift from book stock, and what happens when a station goes past it. In outline, a gain beyond the limit is treated more seriously than a loss, because a gain can mean product that did not come through the books.
PetroKhata shows each tank's variation for the day and the month against a limit, with a status of OK, watch or breach, and raises an alert for a sudden one-day loss even when the month looks fine. The limit formula is our working assumption from MDG 2024, and how the different allowances combine is something we are confirming with sales officers. That is why the rule used is printed on the Annexure 9 page. Use it as an early warning, and take your sales officer's word as final on the actual limit.
When the officer arrives
The question is usually "since the last inspection": what came in, what was sold, how much went into testing, what the stock should be and what the dip says. Gathering that from notebooks takes an hour. In PetroKhata, the Officer's Inspection Report covers the period since the last recorded visit in one page, and the density, variation and daily stock registers print from the same screen. After the visit, record the inspection so the next report starts from that date.
A few habits make the visit shorter:
- Keep the dip rod, water-finding paste, hydrometer, thermometer, measuring jar and the stamped 5-litre measure in one place, clean and ready.
- Keep calibration charts for each tank at the station, not only with the owner.
- Keep current copies of licences and stamping certificates on file. PetroKhata has a licences and certificates list that reminds the owner 30 days before an expiry.
- Never overwrite a figure. If a reading was wrong, correct it with a name, time and reason.
A five-minute morning routine
The routine that keeps the registers clean is short: dips and water dips, density, 5-litre tests, price check, then open the shift. On the screens page you can see the morning checks screen from a demo station, with all three checks on one page.
If you want to see your own station's registers built this way, tell us about your station. We are setting up pilot stations now and will go through your current registers with you before anything changes.
Frequently asked questions
By what time must the morning density be recorded?
The practice most oil companies follow is a density reading for each tank before the first sale and by 10 AM. PetroKhata shows a warning from 9:15 if a tank's reading is missing and records the day as missed if 10 AM passes. Confirm the exact rule for your outlet with your sales officer.
Does PetroKhata print the registers in the official format?
PetroKhata prints Annexure 1, Annexure 9, the daily stock register and an inspection report on A4, in the layouts we built from the guidelines. We are still checking those layouts against the printed annexures the oil companies issue, so compare one month with your current paper register before you rely on it.
Is the stock variation limit in PetroKhata the official MDG figure?
No. The limit PetroKhata uses is a working assumption from our reading of MDG 2024, and the rule is printed on the register so nobody mistakes it for an official number. Ask your sales officer how the allowances apply to your outlet.
Can PetroKhata produce these records without internet?
Yes. The registers and the inspection report are made from the data on the station PC, so they print even when the internet is down.